Sarbatorile vin si eu am ajuns abia la jumatatea cursului de engleza intermediar interactiv. De la Eurocor, desi in ultimile doua luni am avut senzatia ca lectia douazecci va fi si ultima, pana cand m-am uitat mai bine si am vazut ca acest curs are 40 de lectii, 20 de caiete de curs in total, asa ca o sa va mai povestesc multa vreme despre el si despre progresele mele in limba engleza. Voi ati facut vreun curs de la Eurocor? Daca nu, care va tenteaza si de ce? Sfatul meu, daca vreti sa urmati un curs online de la Eurocor este sa profitati de reducerea foarte mare de 55% la pachetele de curs complet si sa-l luati pe tot odata ca sa nu asteptati dupa el. In plus, veti primi si un Smartwatch cadou. SUPORT DE CURS -LIMBA ENGLEZA - NIVEL Incepator - Mediu - Teacher: AndreeaIonel 2 Courses: Virginia Evans, ZSuccessful Writing Intermediate, Express Publishing, Jenny Dooley, Virginia Evans, ZGrammar Way 1 , Express Publishing, Jenny Dooley, Virginia Evans, ZReading and Writing Targets 1 , Express. Service & free calls. This number, only available 3 minutes, is not your correspondant’s number but the number of a service putting you through to that person. Contact people - EUROCOR - INSTITUTUL EUROPEAN DE CURSURI PRIN CORESPONDENTA SRL Download the executives list. CEO - Chief Executive Officer (Director.

  1. Cursuri Eurocor Germana
  2. Cursuri Eurocor Freelancer
  3. Institutul Eurocor

Product extract

  • DIORPaclitaxel-coated
    Coronary dilatation catheter
    Drug-Eluting-Balloon (DEB)
    Paclitaxel-Eluting-Balloon
    The next generation coronary technologies. DIOR, the Paclitaxel coated coronary balloon dilatation catheter, available NOW. The ultimate patient treatment method for treating bifurcated coronary artery lesions, small coronary artery diameter and In-stent Restenosis and the innovative option for bare metal stenting.
    Learn more - visit the product page...
  • FREEWAY 014Paclitaxel releasing over the wire (OTW) PTA balloon catheterFREEWAY™ 014 – latest second-generation drug-releasing technology PTA balloon technology specifically designed for infrapopliteal interventions
    Learn more - visit the product page...
  • FREEWAY 035Paclitaxel releasing over the wire (OTW) PTA balloon catheterFREEWAY™ 035 – latest second-generation drug-releasing technology PTA balloon technology specifically designed for peripheral interventions
    Learn more - visit the product page...
  • Genius MAGICCobalt Chromium
    Coronary Stent System
    The clinially superior cobalt chromium coronary stent system with superthin stent strut design, which ensures optimal neointimal stent protection.The FIRST CHOICE for direct stenting and small vessel diameter.
    Learn more - visit the product page...

Paclitaxel

Paclitaxel prevents restenosis by blocking proper microtubal formation, thus it inhibits cell division and migration. It inhibits inflammatory processes. After balloon dilatation, injuries to the arterial wall stimulate inflammatory reaction, and the excretion of growth factors occurs as an important process along with the onset of cell division and the migration of smooth muscle cells. Paclitaxel inhibits platelet derived growth factor (PDGF) mediated vascular smooth muscle cell migration to the intima. Paclitaxel also inhibits extracellular matrix secretion and breakdown.

What is most important

Paclitaxel selectively inhibits the proliferation of smooth muscle cells. The endothelium cells show a better resistance to Paclitaxel than the smooth muscle cells due to the different affinity of the connective structure on the cell surface. Paclitaxel does not influence non-proliferating cells as a result of cytokine and growth factor stimulation. The FREEWAY Paclitaxel-releasing PTA balloon dilatation catheter enhances a smooth re-endothelialization process.

Axel et al. Circulation 1997.
Paclitaxel inhibits arterial smooth muscle cell proliferation and migration in vitro and vivo using local drug delivery.
Circulation 1997; 96:636-45

Shellac

The excellent film forming properties of shellac are used to coat gastric resistant tablets.

The FREEWAY 014 Bioshell coating matrix consists of a natural resin, which is EMA and FDA approved (GRAS) as food additive under E 904.

Investigation of cytotoxicity

Shellac extraction product
(24 h extraction in cell culture medium)

Quantification of cell quantity
Metabolic cell activity (MTS-assay)

No signs of pro-inflammatory activation

Cursuri de engleza gratis

IL-8-release

Cursuri Eurocor Free

Shellac extraction products (24 h) Exposition of confluent HDMEC with extraction products (24 h) tumour necrosis factor α (TNFα ) as a positive control group

Peters K, Prinz C, Salamon A, Adam A, Stuhldreier G, Rychly J, Neumann H-G.
Evaluation of shellac as coating of intravascular devices –
Testing of in vitro compatibility by endothelial and smooth muscle cells.
Jahrestagung der Deutschen Gesellschaft für Biomaterialien, 8.-10.10.2009, Tübingen

Cursuri Eurocor Germana

Neither direct contact to shellac-coated materials nor exposure to shellac extraction products impaired HDMEC and hSMC viability and function in vitro.

Shellac is a natural resin composed of shellolic and alleuritic acid.

The coating consists of a 1:1 mixture of Paclitaxel with shellac applied to the balloon by a micro-pipetting procedure in a clean room under sterile conditions.

*Very smooth surface – less vulnerable to abrasion

The FREEWAY 014 Paclitaxel releasing balloon catheter

In contact with body liquid the hydrophilic shellac-network of the composite swells and opens the structure for the pressure-induced fast release of Paclitaxel on the inflated balloon.

FREEWAY 014, infrapopliteal PTA balloon 0.014” OTW

How it works

PTA causes vessel wall injury. Hyperplasia of the inner vessel wall resulting in lumen narrowing is the natural reaction to this injury. After the ‘controlled injury’ set by the angioplasty procedure the key pathways start to contribute to the formation of neointimal hyperplasia. Due to injury from cracking plaque material, neointimal hyperplasia can slowly narrow the lesion, causing massive neointimal proliferation in treated lesion area.

After predilatation, the FREEWAY 014 Paclitaxel releasing PTA balloon is advanced to the lesion site.

With the balloon well positioned, inflation for at least 60 seconds releases the anti-proliferative drug.

The balloon is withdrawn as the drug penetrates into the artery wall. Paclitaxel will act immediately, over a short term, to inhibit cell re-growth. The shellac coating remains on the balloon.

The science of FREEWAY 014 – shellac conclusion

Cursuri Eurocor Freelancer

1:1 mixture Paclitaxel with shellac: proven and safe short-term drug release

Paclitaxel is applied in a final concentration of 3 μg/mm2 to the surface of the balloon.
Tissue concentrations of Paclitaxel reached by this coating is inflation time dependent.

After 60 seconds of balloon inflation a concentration of 200 μM/L is reached.
Posá et al.: Catheterization and Cardiovascular Interventions 76:395-403 (2010)
It is important to mention that after 120 seconds of balloon inflation time this concentration is even more than doubled.**
For peripheral treatments Eurocor recommends at least two minutes of inflation time; in severe cases it should be considered
to prolong the inflation time up to 180 seconds (in-stent restenosis and infrapoploteal lesions).
** Eurocor data on file

FREEWAY 014 – OTW balloons for successful infrapopliteal interventions

A treatment concept with optimal developed products

  • low balloon crossing profile
  • low tip entry profile
  • short deflation time
  • hydrophilic shaft coating

Reach your destination with an enhanced OTW 0.014” balloon designed to cross smoothly and deflate quickly.

Balloon crossing profile

Low-primary crossing profile - excellent trackability and flexibility

Low-profile tapered tip for easier lesion crossing - excellent crossability and navigation of infrapopliteal vessels including case of challenging anatomy

Institutul Eurocor

Greatly reduced deflation

Superior deflation time compared to competition - for fast and safe treatments

Cursuri eurocor free trial

FREEWAY 014, infrapopliteal PTA balloon 0.014” OTW

Latest, second-generation drug-eluting technology with an immediate short-term drug release effect

An innovative therapeutic treatment concept with excellent trackability for challenging infrapopliteal lesions

Cursuri

Ultra-low profile balloons specifically designed for infrapopliteal interventions

  • 2–4 mm balloon diameter
  • 40–150 mm balloon length
  • 120 cm and 150 cm shaft lengths

FREEWAY 014, infrapopliteal PTA balloon 0.014” OTW

An innovative concept with many benefits:

  • Delivers drug locally over a short period of time
  • Avoids chronic inflammation
  • Simplifies the procedure – is as easy to use as a standard PTA balloon catheter
  • Crosses lesions smoothly due to the low profile
  • Respects original vessel anatomy
  • Treats lesions where stents are not a viable solution
  • Allows short-term antiplatelet therapy
  • Reduces the incidence of restenosis
  • Enables re-intervention